Chemical Gases Calibration
Introduction
- Chemical-Gases calibration has wide & large scope covering parameters to meet the Industrial / Laboratory requirements.
- Our Lab have Traceable Standard Instruments to calibrate Chemical & Gas parameters.
- We have facilities for calibrating parameters like pH, Conductivity, Breath Alcohol, DO(Dissolved Oxygen) & Gases like Oxygen, Carbondioxide and some combustible & toxic gas detectors.
- On-Site Calibration Facility with well trained calibration officers.
- We have catagorized our calibration into 2-Groups.
- Facilitated with separate Calibration Sections for both groups.
- Site Calibartion facility for Flame Photometer & ELISA Reader available.
- Calibration of pH Meters, Conductivity, Turbidity, Breath Alcohol Tester, ORP, DO are available for Lab facility.
- Calibration of Gas Meters / Detectors / Analyzers, Multi-Gas detectors, Flue Gas analyzers & Stack Emission analyzer.
- To Fulfill Industrial / Laboratory related requirements, we have low range for below mentioned parameters:
1. Conductivity -1.3 µs/cm
2. Turbidity -0.5 NTU
3. Oxygen Detectors- 0%
Recognition & Accreditation
Accredited vide FDAS Cert No. CL-103
“Federation for Development of Accreditation Systems(FDAS)” has been established as a nongovernment organization under section 9(1) of the Haryana Registration and Regulation of Societies Act 2012 vide registration number HR / 018 / 2019 / 03652 on 27th March 2019 with its own legal identity.
Customer Instruments Calibrated
- pH Meter
- Conductivity Meter
- TDS Meter
- Turbidity Meter
- Dissolved Oxygen (DO) Meter
- Digital/Analog Refractometer
- Digital Salinity Tester
- Breath Alcohol Tester
- Oxygen Reduction Meter (ORP)
- Gas Detectors
- Gas Analyzers
- Multi Gas Detector
- Flue Gas Analyzer
- Stack Emission Analyzer
- Flame Photometer
- ELISA Reader
Chemical Calibration Parameters
- pH - 4.0, 7.0, 10.0 pH
- Conductivity- 1.3, 10, 75, 100, 1000, 1413, 10000, 100000, 200000 µs/cm
- Total Dissolved Solids- 50, 67, 300, 665, 941, 3000, 6661, 66618 ppm
- Turbidity- 0.5, 100, 1000 NTU
- Dissolved Oxygen(DO)- 0%, 100%
- Refractometer- 2.5%, 15%, 40% BRIX, RI:1.46839
- Salt Tester- 5, 25, 45ppt
- Breath Alcolhol- 0.02, 0.04, 0.08, 0.2g/dL
- Oxygen Reduction Potential- 86, 263, 475mV
Gases Calibration Parameters
- Oxygen (O2)- 0%, 1%, 20.8%, 100%
- Carbondioxide (CO2)- 500 ppm, 10%, 100%
- Carbonmonoxide (CO)- 100, 1000ppm
- Hydrogen Sulphide (H2S)- 15, 25ppm
- Methane (CH4)- 5000 ppm(10% LEL) & 25000ppm(50% LEL)
- Propane (C3H8)- 2100 ppm(10% LEL) & 10500ppm(50% LEL)
- Nitric Oxide (NO)- 30, 200ppm
- Nitrogen Dioxide (NO2)- 100ppm
- Sulfur Dioxide (SO2)- 1000ppm
Calibration Parameters Onsite
- Flame Photometer
1. Calcium- 0 to 1000 ppm
2. Sodium- 0 to 160 ppm
3. Potassium- 0 to 1000 ppm
4. Lithium- 0 to 1000 ppm
5. Barium- 0 to 1000 ppm
- ELISA Reader
1. Absorbance- 0.3 to 2.0 AU
2. Wavelength- 240nm to 640nm